FlowLine EchoTouch
Ultrasonic Level Transmitter
- Intrinsically Safe Transmitter (Ex ia)
- US06 Range 20cm to 6m
- US12 Range 50cm to 12m
- Display LCD, Push Button
- Output 4-20mA, Fail-Safe
- Supply Voltage 14-28VDC
- IECEx Certificate IECEx CSA 18.0008X
MicroSensors MPM426W
IS Hydrostatic Transmitter
- Intrinsically Safe Transmitter (Ex ia)
- Range from 0...2mH₂O, 0...200mH₂O
- Housing & Diaphragm AISI316L
- Cable Options PE, PVC, PUR, PFA
- Output 4-20mA (2-wire)
- Supply Voltage 12-28VDC
- IECEx Certificate IECEx CSAE 22.0019
Tecfluid SC250
Intrinsically Safe Flow Meter
- Flow Transmitter Intrinsic Safety "ia"
- Output 4-20mA (2 wire)
- Power Supply 14...30VDC
- Flow Water 2.5 l/hr...180m³/hr
- Flow Air 75 Nl/hr...5,400 Nm³/hr
- IECEx Certificate IECEx LOM 18.0006X
Georgin BXNT Series
IS Convert 2 Wire Transmitter
- Input Signal Options 0/4-20mA, 0-5/10V
- Output Signal Options 0/4-20mA, 0-5/10V
- Power Supply ≥15VDC Hazardous Area
- Power 230VAC, 110VAC, 24VDC, 48VDC
- Mount DIN Rail, 21.5mm Wide, Safe Area
- IECEx Certificate IECEx LCI 09.0013X
Georgin RDN Series
IS Digital Input Barrier
- Digital Input from Hazardous Area
- Intrinsically Safe Galvanic Isolated Relay
- Inputs Contact & Proximity Sensor (NAMUR)
- Output Relay (5A/250V) or Transistor (5kHz)
- Power 230VAC, 110VAC or 24...48VDC
- Single or Dual Channels
- IECEx Certificate IECEx LCI 09.0013X
Georgin BXE Series
Intrinsically Safe Power Supply
- Power Supply in Hazardous Area
- From 7.2 to 23.5VDC Hazardous Area
- Eg. Solenoid, Pilot Lamp, Transmitter
- Optional Remote Control
- Single or Dual Channels
- SIL2 Classification to IEC 61508
- IECEx Certificate IECEx LCI 09.0013X
Georgin S5DI Series
Temperature Transmitter
- Range from -200°C to +600°C
- Sensing Element RTD, Ni, Tc
- Head Aluminium Epoxy Coated
- Sheath AISI316L, ∅6mm or ∅8mm
- Connection ½" BSP/NPT with Extension
- Optional TiXo IS Transmitter Puck (IECEx)
Georgin TiXo1/2/3 Series
Intrinsically Safe Temperature Puck
- Temperature Transmitter 4-20mA Output
- Input RTD, Ni, Tc, Voltage, Resistance...
- Configurable Options PC or Hart
- Housing PBT, ∅44mm x 21.6mm (h)
- Three Types TiXo1B, TiXo2B, TiXo3B
- IECEx Certificate IECEx INE 14.0024X
Georgin BXNR/C/P Series
Pt100, TC & Potentiometer Converter
- BXNR Pt100 (RTD 100 Ω) Input
- BXNC Thermocouple E, K, N, S, J, R, T
- BXNP Potentiometer from 0-1kΩ to 0–50kΩ
- BXNV Variable Resistor
- Signal Output 0/4-20mA, 0-5/10V
- IECEx Certificate IECEx LCI 09.0013X
Micro Sensor MDM7000-DP
Differential Pressure Transmitter
- Diaphragm Mat. AISI316L, HC-276, Tantalum
- Range Min 2 mbar / Max 100 bar
- Turn Down 100:1 (≥0.4 bar)
- Accuracy ±0.05%, ±0.075%URL
- Output 4-20mA, HART, Bluetooth, Modbus
- IECEx CSA 24.0045X (intrinsic safety)
- Local LCD Display & Push buttons
Micro Sensor MDM490
Differential Pressure Transmitter
- Diaphragm Matetrial AISI316L
- Differential Min Range 0...40kPa
- Differential Max Rang 0...3.5MPa (35 bar)
- Max. Static Pressure ≤20MPa
- Accuracy ±0.5% FS
- Output 4-20mA (Optional Volatage)
- IECEx CSA 25.0041X (intrinsic safety)
Tecfluid COVOL
Oscillating Piston Flow Meter
- Flow Rate 25 l/hr...60 m³/hr
- Material AISI316L, PTFE, PP or PVC
- Pulse Output Reed Switch (dry contact)
- Accuracy ±0.8% Measured Value
- Repeatability ±0.3%
- Viscosity up to 120,000 mPas